Test Condition |
300µs, 300Hz, 9% DC, 25°C |
Optical Parameters |
Centroid Wavelength λ |
nm |
940 |
Output Power 2 |
W |
>4 |
Output Power Decay |
%/°C |
-1.97 |
FOV @ FWHM (Typical Horizontal x Vertical) |
° |
120x20 / 120x60 (Top Hat), 60x45 (Cos-2) |
Spectral Width FWHM |
nm |
<3 |
Wavelength Temp. Coefficient |
nm/°C |
0.08 |
Electrical Parameters |
Threshold Current Ith |
A |
<0.7 |
Operating Current Iop |
A |
6 |
Forward voltage Vop 3 |
V |
<2.5 |
Slope efficiency 3 |
W/A |
>0.8 |
Power conversion efficiency |
% |
>32 |
PD |
PD Forward Voltage |
V |
0.5-1.3 |
PD Reverse Breakdown Voltage |
V |
35 |
PD Reverse Dark Current |
nA |
2-10 |
PD Junction Capacitance |
pF |
2-10 |
PD Peak Sensing Wavelength |
nm |
940 |
Others |
Operating Temperature |
°C |
-40~105 |
Remark: 1 FL(abbreviation of Focuslight) - AT02 (structure code) -N (chip power) -- ## (center wavelength)- H xV (FOV) 2 A non-condensing environment is required for storage and operation below ambient dew point. |