Laser beam data |
|
Wavelength(1) |
10.6µm |
Excitation |
RF |
Output power |
|
Power range (typical rated) |
20W-350W(6) |
Typical power stability |
± 5.00% |
Typical Power stability with power feedback |
± 1% |
Guaranteed power stability |
± 7% (± 2%(5)) |
Peak power |
> 880W |
Minimum shipment power(4) |
420W |
Typical shipment power |
465W |
Laser beam quality |
|
Diameter @ (1/e2) |
7.0 ± 0.5mm |
Beam quality factor M2 (K) |
M2< 1.2 (K > 0.8) |
Divergence (full angle) |
< 2mrad (1 to 10m) |
Pointing stability (half angle)( 3 ) |
< 0.25mrad |
Polarisation |
linear (45° base) |
Ellipticity |
< 1.2:1 |
Pulsed mode(2) |
|
Frequency |
0kHz –130kHz |
Width |
2µs –400µs |
Energy |
14mJ–280mJ |
Optical pulse rise/fall(7) |
< 60µs |
Duty cycle (max) |
60% |
Dimensions and weights |
|
Laser head |
(LxWxH) 1178mmx263mmx232.5mm approx. 63kg |
Combined RF/DC unit |
(LxWxH) 613mmx487mmx259mm approx. 65kg |
RF |
(LxWxH) 490mmx371mmx80mm approx. 17kg |
External control facilities |
|
Laser head |
Commands from external controller Status signal to external controller PWM control(5) NC control (0–10V)(5) |
DC Electrical ratings – 3 phase water cooled |
|
Input Voltage Range |
400VAC ± 10%. 3 phase 50/60Hz (three phase–no neutral) |
Maximum output current |
150A |
Maximum output power |
7.5kW |
External fusing requirement |
20A fuse per phase |
Earth leakage current |
< 6mA OR |
Cooling |
|
Flow rate |
³ 360L/hr (laser head) |
Refrigeration capacity |
³ 8.3kW |
Temperature |
19°C/66°F to 25°C/77°F ± 1K (above dew point) |
Notes : 1. 10.6µm is the predominant wavelength. This can typically vary in the range 10.45µm–10.7µm 2. Minimum and maximum optical modulation depths are frequency and duty cycle dependent – minimum depth occurs at short pulse widths and high frequency. For the SCX 35 the following optical modulation depths are typical: a.10kHz–44 to 100%, b.30kHz – 17 to 100%, c.60kHz – 11 to 71% 3. The pointing stability stated is based upon the full range of available pulse widths. At a fixed pulse width stability will be significantly better 4. Mean average power at maximum duty cycle 5. When supplied with power feedback assembly. (Turn on response is typically 300 to 500 milliseconds) 6. Minimum power with power feedback is 25W 7. Quoted from 10-90% level |