FLEX-GUARD® Laser Curtains
FLEX-GUARD® Laser Curtains
產品名稱 : FLEX-GUARD® Laser Curtains
產品說明 :
Flex-Guard® laser barriers and laser curtains are constructed from heavy-duty, single layer fabrics with matte finish in either standard black color or our professional-looking “Tech Blue”. The materials are notable for flame retardance, chemical resistance, abrasion resistance, and non-fraying characteristics. Laser safety curtain and laser barrier panels are individually sewn with heavy gauge monofilament threads. All seams are double stitched with back-stitched ends to improve strength and durability. Hems and seams are folded flat and pressed before stitching to ensure a “pucker-free” appearance.
● Low, Medium, High Power Ratings
● Opaque Satin Finish Absorbs and Diffuses Laser Beams
● Heavy-Duty Coated Fabric is Ideal for Blocking Diffuse and
● Low Power Laser Radiation
● Stock and Custom Sizes Available
● Meets ANSI Z136 and CE EN12254 : 2010 Certified
● Certified to NFPA 701:2010
● CE EN60825-4 Certified
*** Each system is built to individual requirements and is available in any width and height up to 10 feet. ***
More detail products information please contact with our services center. E-mail: unicehq@unice.com.tw
Fabric and Stitching
● Extra heavy-duty flame retardant, non-fraying and chemical resistant flexible fabric
● Double-stitched seams; ends back-stitched to improve strength
● Lock stitches ensure durability and will not unravel
● Hems are folded flat; pressed seams are guaranteed to be “pucker free”
Roller-Rail Track
● Steel track system is comprised of straight pieces, curves, end stops, by-pass rollers and connectors
● 16 gauge steel track components have a non-reflective black matte finish
● Engineered track channel ensures smooth and directional operation of rollers
Components
● Heavy gauge (20 mil) dusted vinyl pocket-style window for signage or equipment documentation
● Non-reflecting black #1spur-style steel grommets lay flat and hold tight
● #10 Nylon heavy-duty zippers available with locking rings
● Velcro® hook and loop fasteners
Options
● Interlock systems (i.e. proximity switches and Ademco switches)
● Ceiling-, floor- or wall-mount track options
● Doors and windows, including laser-safe viewing ports
● Velcro®, zippered or plain seams
● Valance and tie-backs
● ESD panel grounding
● Non-load bearing roof
● Secure, interlocked access points
● Magnetic zipper access
Sample
Material Options
Selection | Kentek P/N | Description | Certifications |
---|---|---|---|
25 Watts/cm2 Matte Black FLEX-GUARD® | SLC-25W-B | Low Power Black, matte finish | NFPA 701:2010 TM1, ANSI Z136 25W/cm2 for 100 seconds |
50 Watts/cm2 White FLEX-GUARD® | SLC-50W-W | Medium Power White matte finish | NFPA 701:2010 TM1, ANSI Z136 50W/cm2 for 100 seconds |
100 Watts/cm2 Matte black FLEX-GUARD® | SLC-100W-B | Regular Power Black matte finish | NFPA 701:2010 TM2, ANSI Z136 100W/cm2 for 100 seconds |
CE EN12254:2010 D AB8 190-315, R AB2 190-315, D AB6 >315-1050, IR AB6 >315-1400, D AB4 >1050-1400, DR AB2 >1400-1110 | |||
CE EN60825-4 | |||
100 Watts/cm2 Tech Blue FLEX-GUARD® | SLC-100W-L | Regular Power Blue, matte finish | NFPA 701:2010 TM2, ANSI Z136 100W/cm2 for 100 seconds |
250 Watts/cm2 Matte Black FLEX-GUARD® | SLC-250W-B | Plus Power Black, matte finish | NFPA 701:2010 TM2, ANSI Z136 250W/cm2 for 100 seconds |
CE EN12254:2010 D AB9 190-315, R AB3 190-315, D AB6 >315-1050, IR AB7 >315-1400, M AB7 >315-1400, D AB5 >1050-1400, DR AB3 >1400-11100 | |||
CE EN60825-4 | |||
Non-Laser Blackout Matte Black BBK II | SLC-BBKII | Non-laser room darkening, black, matte finish, woven material | NFPA 701:2010 TM1 |
Non-Laser Blackout Tech Blue LBL | SLC-LBL | Non-laser, blue, matte finish | NFPA 701:2010 TM1 |
Choose From 9 Standard Laser Access Point Styles or Customize Your Own!
There are many elements to think about when designing curtains for a laser area, but one that often gets overlooked is how to gain access into the laser area. We offer 9 standard laser curtain access point styles, ranging from simple curtain overlaps to secured access-controlled doorways, and we will customize to meet your requirements.
Laser Curtain Access Points - Standard Styles
Rigid Magnetic Door The Rigid Magnetic Door (RMD) can be used with most Flex-Guard® and Ever-Guard® laser barrier curtain systems. The RMD creates an entry point for a Laser Controlled Area and can be mounted either into the curtain run or terminated at a wall. It is the best solution for high traffic areas or when secured access is required. Entry buttons, keypads or electromagnetic locks can be mounted directly to the door system and wired to an access control system. |
|
Shared Grommet Overlap The Shared Grommet Overlap works with our Flex-Guard® laser barrier curtains. It consists of two curtain sections sharing common grommets along the top, overlapping each other by 12-inch. This creates an overlap that can be separated and passed through. The curtains then hang back to their overlapping position, keeping the opening light tight. The Overlap entry is not recommended when interlocks are prescribed. |
|
9-Inch Single Bypass The 9-Inch Single Bypass is created by installing a special roller assembly with a 9-inch projecting arm that allows one curtain panel to move behind a second conventionally mounted curtain panel. The hardware is shaped to enable a 9-inch overlap when the two curtain panels are pulled into the closed position. The two panels are easily separated for entry or egress. |
|
18-Inch Double Bypass The 18-Inch Double Bypass utilizes two pieces of specialized roller hardware to allow curtain panels to overlap each other. Each roller assembly has a 9-inch projecting arm that allows one curtain panel to move behind another panel, creating an 18-inch overlap when the curtain is in the closed position. The double bypass can be fitted with a micro switch to interlock the curtain. |
|
Velcro® Velcro® brand hook and loop fasteners, 1-inch width, may be used to create an access point in a laser barrier curtain. Curtain panels may be joined together with hook and loop along their entire height, or the fasteners may be used to connect a curtain to a wall or other fixed point. |
|
Zipper Zipper access points are available for our flexible and our metal curtains. Pull the zipper up to open the panels, pull the zipper down to close. The area can be secured with a lock between the zipper pull and an optional D-ring at the curtain bottom, but you should ensure your lab has adequate emergency egress. |
|
Magnetic Zipper The Magnetic Zipper access point is fabricated with specially designed strips of rare earth magnets sewn onto adjacent curtain panels. These strips are strong enough to keep the laser curtain light tight, but users can pull apart and open the curtain panels with relative ease. Separate the curtain panels and walk through; the curtains will hang back to their original positions and the magnetic strips will close together with no need for manual alignment. |
|
Half-Zip Custom combinations of Zipper and Velcro® or Zipper and Magnetic Zipper are used when tall curtains need to be opened fully to allow for equipment to be moved in and out of the Laser Controlled Area. In these situations, completely unzipping the curtain is difficult because the curtain top is out of reach; having a combination of a Zipper and Velcro® or Magnetic Zipper allows the curtain to be unzipped to a designated height and then the Velcro® or Magnetic Zipper is separated the rest of the way. |